Equalogic Backup Drive

From Research Computing Center Wiki
Jump to navigation Jump to search

Objective

Leverage the Burke Lab iSCSI device to add to and assist with the migration of the GACRC SAN from 10.0.0.0/8 IP addresses to 192.168.0.0/16 IP addresses. This needs to happen because the SAN VLAN is unable to be monitored. A monitoring node cannot have interfaces on separate networks with the same IP addresses and the 10.0.0.0/8 network is already used on the internodal network (VLAN 40).

Completed

  • Remove Franklin configuration
  • Configure ports in the Thumper Rack for VLAN 31
  • Configure IP addresses
  • Add VMKernel interfaces with 192.168/16 IP addresses to ESX hosts
  • Create LUNs
  • Attach LUNs to VMWare Hosts
  • Begin Migrating VMs
  • Monitor LUN Latency and adjust
  • Gave Burke iSCSI unit definition in Rocks
  • Name: gacrc-iscsi-2
  • MGMT IP address: 172.16.33.114
  • iSCSI Access IP addresses: 192.168.0.1, 192.168.0.2, 192.168.0.3, 192.168.0.4 netmask 255.255.0.0

Need to be Completed

  • Migrate ALL VMs
  • Remove LUNs from Hosts and reboot them, one host at a time
  • Change Equalogics IP addresses
  • Reattach Equalogics to Hosts and reboot them, one host at a time
  • Migrate some or all VMs back
  • Decide based on LUN latency how to proceed with storage provisioning

Notes

  • Use Burke iSCSI as Virtual Machine backup?
  • Use Burke iSCSI as exports for Gluster?
  • Use Both Burke iSCSI And Equalogics for VMWare